ETA Logo  
   
  DC Inverter  
  Helps Shortest Route Design Free Branching  
 
Combination of line and branching pipe connection makes the shortest design route possible, thereby saving on installation time and cost.
 
  Simple Wiring  
 
Multiplex communication system makes it possible to connect multiple indoor units to one outdoor unit with a 2-core wire, thus simplifing the wiring operation.
 
     
  High Lift Design  
 
175 m Equivalent length and 50m Height difference is allowed in ETA GREE GMY. Level difference between indoor units of 15m makes the location of the system more flexible.
 
  Energy Saving  
  Each room can be controlled individually, so that only those rooms requiring air conditioning are cooled or heated.lnaddition,thanks to the stepless regulation technology of ETA GREE and EXV (Electronic Expansion) applied in both indoor and outdoor units. The temperature of each room can be precisely controlled. High IPLV is achieved by employing cutting-edge technology, and contributing to smooth and economical operation. The highest IPLV value 4.6 W/W (15.69 BTU/W-hr) ,compared with the conventional chillerfan coil system, a large energy saving can be realized  
  Self Diagnostics System  
  Comprehensive troubleshooting code was displayed when problems happen.
Self diagnostics examples
Errorcode Nature of malfunction
El Compressor high pressure protection
E2 Indoor unit anti-freeze protection
E3 Compressor low pressure protection
E4 Compressor discharge temperature protection
ES Compressor over loading protection
E6 Communication error
 
  Compact Design  
 

We offer a wide range of outdoor and indoor units to meet the needs of building size and interior design. Long refrigerant pipe is applicable to ensure better flexibility.

In most situation, no special cranes or conveyer is needed to lift the outdoor unit to the roof as it can be carried by elevator in the building thanks to compact design.

Compact connection refrigerant piping system ensures GMV with great advantage of saving ceiling space, especially in low profile buildings.

 
  Intelligent Control  
 

ETA GREE GMV intelligent controls and modulating valves deliver the required capacity, according to the load varia­tion from 10% to 100%. The intelligent controls and modulating valves limit or increase the cooling capacity dynami­cally, so humidity and temperature are kept in the comfort range.

Electronic expansion valves respond to the changes in load of indoor units and continually control the flow rate of refrigerant. In this way, we can get a nearly constant room temperature with the GMV system without common temperature fluctuation that occurs with a conventional ON/OFF control system. The precise PID controls maintain the room temperature within ±O.soC of the set temperature.

 
  Wide Control Application  
 
  • Intelligence Network system
  • Central control available ( provided with weekly timer function)
  • Network monitoring system available
  • Wireless remote controller or wired controller of indoor units
  • Diagnostic software for service purpose is known as Debugger S/w
  • Region wise wired controller i.e. Smart Zone controller
 
  Larger capacity  
  Rm series and Pdm series are modular design. Maximum 4 basic modules can be freely combined together to achieve max. Capacity of 180kW. (64 Hp) With advanced controls, the outdoor modules have no differences & there is no need  
  DC Inverter fan  
  Thanks to high-efficiency DC inverter fan motor, the outdoor units are high efficiency and low noise; the ESP(external static pressure) is up to 50Pa, that ducting installation for hot air exhaust can be satisfied.  
     
  Download PDF here download PDF  
  Accreditations from                         ce      
     
About Us Air Conditioning Products MEP Contracting Commercial Projects Manufacturing
Company Profile
History
Corporate Purposes
Values & Briefs
Corporate Safety Policy
Corporate Social Responsibility
Milestones
Group Companies

Work with us
Careers @ ETA
Employee Development
Job Opportunities
Residential
Window Air Conditioner
High Wall Air Conditioner
Cassettes :
Cassettes AC
Light Commercial
Ducted Split Unit:
Air-cooled
  R22
  R407C
Water-cooled
  R22
  R407C
Floor Mounted Packaged Air-conditioner
Air-Cooled
  R-22
  R-407C
  Super EER
Water-cooled
  R-22
  R-407C
Roof Top Packaged Air-conditioner
  R-22
  R-407C
VRF
  DC inverter
  Digital Scroll
Heavy Commercial / industrial
Chillers
Air-Cooled
  R-22
  R-407C
Water-Cooled
  R-22
  R-407C
Air Handling Units
VRF
  DC inverter
  Digital Scroll
Fan Coil Unit
Chilled Water Cassette
HVAC
Electrical
Plumbing

Facilities Management
Cold Storage
 
Offices
IT / ITES
Retails – Malls & Multiplexes
Hospitals
Hotels
Educational Institute
Banks
Automobile

Infrastructure Projecs
Builders
Airports
Metro Rail
Telecommunications
Special Economic Zones (SEZ). Power Plants

Industrial Projects
Pharmaceuticals
Steel Plants
Electronics / Semiconductor
Defense
History & Overview
Manufacturing Philosophy
Manufacturing Facilities
Manufacturing Equipments
R & D
Test Facilities
Contract Manufacturing
Initiatives
Customer Services (AMC)
Standard Services
Contract Condition
Upgrades & Enhancements